Skip to main content

Licensing

DigiCert​​®​​ Software Trust Manager is based on a subscription licensing model. For updates to your license agreement, contact DigiCert Sales.

Signature units

Signature units are relative to the number of hashes that are signed with a production keypair. Every hash that you sign will consume one signature unit.

Nota

Signature units have a soft limit. This means that you are not restricted to the unit amount in your account and can exceed it however you will incur overages.

Test signature units

Test signature units are relative to the number of hashes that are signed with a test keypair. Every hash that you sign will consume one signature unit.

Nota

Test signature units have a soft limit. This means that you are not restricted by the unit amount in your account and you can exceed it, however you will incur overages.

Cryptographic units

Cryptographic units is a count of all operations performed by an account which are related to cryptographic assets excluding signatures.

Cryptographic events include:

  • Create a keypair

  • Update a keypair

  • Export a keypair

  • Import keypair

  • Create a certificate

  • Update a certificate

  • Import a certificate

  • Revoke a certificate

  • Generate a CSR

Nota

Cryptographic units have a soft limit. This means that you are not restricted to the unit amount in your account and you can exceed it, however you will incur overages.

HSM keypair units

HSM keypair units refer to how many keypairs you create on our HSMs. We provide sufficient space for the number of public trust certificates you are licensed to create as part of your DigiCert​​®​​ Software Trust Manager license. The more signature units you buy, the more public certificates and HSM keypair space you will be allocated.

Nota

HSM keypair units have a hard limit. This means that you will be restricted to the amount of units in your account and you cannot exceed it unless your license is amended by contacting Sales.

Notifications

You can personalize your email notification preferences for monitoring your production signature unit and HSM unit consumption. While the final notification occurs when you exhaust your units, you also have the option to request advance notifications as you approach your account limit.

To specify the licensing thresholds that trigger email notifications:

  1. Sign in to DigiCert ONE.

  2. Select the Manager menu (top right) > Software Trust.

  3. Navigate to: Account > Notifications.

  4. Next to License limits, select the edit icon.

  5. Specify the thresholds you want to be notified for.

  6. Select Update.